4mm Fire-Rated Anti-Static ACP Panel

4mm Fire-Rated Anti-Static ACP is manufactured for Fire-sensitive technical rooms, controlled interiors and fabricated enclosures. The panel build and factory processing can be confirmed around the finished component requirements.

  • Panel thickness: 4mm
  • Standard size: 1220 × 2440mm (4 × 8 ft)
  • Aluminium skins: 0.15mm front + 0.15mm rear
  • Coating: Special anti-static paint coating on both aluminium skins
  • Core: Mineral-filled fire-rated core
Product Overview

What Is 4mm Fire-Rated Anti-Static ACP Panel?

The 4mm fire-rated anti-static ACP panel combines 0.15mm front and rear aluminium skins, double-sided anti-static paint coating and a mineral-filled fire-rated core. It is intended for controlled technical interiors that require both a defined surface-resistance target and a documented fire-performance specification within one ordered panel build.

The anti-static coating is specified around an approximately 10⁶–10⁸Ω target range, while the core classification must be confirmed against the exact skins, coating, thickness and applicable test documentation. These requirements should be ordered together so the supplied panel identity matches the project’s technical submittal and fabrication drawings.

Product Data

Technical Specifications

ItemAvailable specification
Panel thickness4mm
Standard sheet size1220 × 2440mm (4 × 8 ft)
Available widths1000mm, 1250mm, 1500mm and 1570mm
Available lengthUp to 6000mm, subject to confirmed specification and transport requirements
Aluminium skin thickness0.15mm front + 0.15mm rear
Surface coatingSpecial anti-static paint coating on both aluminium skins
CoreMineral-filled fire-rated core
Colour / finishAnti-static coated colour, subject to approved sample
Recommended useFire-sensitive technical rooms, controlled interiors and fabricated enclosures
Factory processingCutting, sizing, routing, grooving and drilling to approved drawings
Target surface resistanceApproximately 10⁶–10⁸Ω, subject to confirmed coating specification and test method
Fire classificationTo the confirmed tested panel build and supporting documentation

Key Advantages

4mm Fire-Rated Anti-Static ACP Benefits

01

Combined Performance Build

The panel brings a mineral-filled fire-rated core and double-sided anti-static surface treatment into one confirmed 4mm construction.

02

Documented Fire Specification

Core, skins, coating and panel thickness can be matched to the applicable classification and supporting test documents requested for procurement.

03

Controlled Surface Resistance

The anti-static coating is selected for an approximately 10⁶–10⁸Ω target range under the agreed measurement conditions.

04

Coated Front and Rear Skins

Both aluminium surfaces receive the anti-static paint system, maintaining the same specified surface treatment on each side.

05

Fabricable Technical Panel

The 4mm sheet can be cut, routed, grooved and drilled into wall modules, covers and equipment-area components.

06

Order Traceability

Confirming rating, coating, resistance target and fabrication as one order helps technical buyers maintain panel identification across supplied parts.

Where It Is Used

Typical Applications

Fire-Sensitive Technical Rooms

Supports selected wall and enclosure panels where fire documentation and anti-static surface control are both required.

Data Centre Support Areas

Can be specified for technical-room walls and service-zone components around electronic infrastructure.

Electronics Production Interiors

Provides a fabricated anti-static surface for designated production-room panels subject to the required fire specification.

Laboratory and Control Rooms

Offers a combined panel option for controlled spaces requiring documented material properties and cleanable wall surfaces.

Product Questions

Frequently Asked Questions

Which fire rating does this anti-static panel provide?

The rating depends on the exact mineral-filled core, aluminium skins, coating and panel build. The required classification and supporting test document must be confirmed with the order.

Does the fire-rated core change the anti-static coating?

No. The front and rear aluminium skins still use the special anti-static paint system; the mineral-filled core changes the panel’s internal construction.

What surface-resistance range can be specified?

The coating described for this product targets approximately 10⁶–10⁸Ω, subject to the agreed coating specification and test method.

Can fire-rated anti-static sheets be factory processed?

Yes. Approved cutting, routing, grooving and drilling can be completed while retaining the product and batch identification required for procurement records.

What information is needed for a quotation?

Provide the fire classification and document requirement, resistance target, dimensions, quantity, colour, processing drawings and intended technical environment.

Project Enquiry

Request a Quote for 4mm Fire-Rated Anti-Static ACP

Send the required panel dimensions, quantity, aluminium skin thickness, target surface-resistance range and test method, core specification, and any processing drawings. Alcadex will review the confirmed build and prepare a manufacturing quotation for 4mm Fire-Rated Anti-Static ACP.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Category: